Completed works

Completed works on seismics

Specialists of the company "AtomSeismicProject" have decade-long experience of testings, certificating and calculating seismic resistance, strength, reliability, climatic and mechanical external influences and also developing and implementating technical decisions of seismic safety and protection of various technological equipment, pipes and building constructions at power facilities. We are ready to be creative while qualifying seismic equipment and to offer the most optimal price and amount of qualification based on normative documents' requirements and standards and also desires of the client. If necessary we will develop test procedure and seismic resistance calculations of optional equipment.

The task of our company - is to provide our clients with convenient and favorable conditions of co-operation. We guarantee positive results of certification meeting the requirements of any commissions and inspection bodies. During many years of our work there were not any claims, only successful co-operation and only positive feedbacks from our clients and partners.

Перед Вами представлены лишь некоторые из выполненных за последнее время работ:
Fire valves - seismic resistance
Fire valves - seismic resistance

"Тrest Belsantehmontazh №1", JSC

Meet the requirements 

  • of state standard 30546.1-98, 30546.2-98, PNAE G 7-002-86, NP-031-01,  in the field of seismic resistance in seismic influences of the MRZ level, set-point in accordance with floor response spectrum for the Belorussian NPP;
  • requirements in the field of resistance for mechanical external factors (OWS, PS) set-point in accordance with floor response spectrum for the Belorussian NPP;
  • I category seismic resistance on N P-031-01.
  • save its strength and working-capacity in the regimes: PA, NE+MRZ,NNE+MRZ

Wireway - climatic tests
Wireway - climatic tests

«RTK-ELEKTRO-М», LLC

Wireways with cast insulation of the type TPLA-10-3150-161 UHL1 with cover sheet Line-X XS-152 meet the requirements of the standard PJSC «FSK ЕES» STО 56947007-29.120.60.106-2011 p. 7, climatic version UHL, location category 1 state standard 15150-69 p.p. 3.2 and 3.6 and technical requirements TU 3414-002-66892460-2014 in the field of resistance to external climatic influences.

 

Isolation valves - seismic resistance calculated analysis
Isolation valves - seismic resistance calculated analysis

"East Reinforcement Company", LLC

There was made calculated analysis of seismic resistance of the items series of isolation valve DN 50, DN 200, DN 1000. There were defined resonance frequency, vibration modes and dynamic loads on items. Globe valves meet the requirements of seismic resistance state standard 30546.1-98 in seismicity site 9 points on a scale MSK-64. The calculations were made according to requirements of PNAE G-7-002-86, NP 031-01, NP-068-05. There was estimated the strength of heavy duty fabricated assemblies: bolt joints of inlet connections, globe valve ventilation pipes in case of its and brackets welding.

Air drives - seismic resistance
Air drives - seismic resistance

"Samaravolgomash", LLC

Modular air drives SVM PPM10000.1-111-11-110DC11-111(112) meet the requirements state standard 30546.1-98, PNAE G 7-002-86, NP-031-01  in the field of resistance to seismic influences intensity 9 points on a scale MSK-64 and setting items in buildings elevation up to +30,0 m

LCD - complex tests
LCD - complex tests

There were madecomplex climatic and mechanical tests of the low-voltage complete device on influences of high and low temperatures, humidity, rain, vibration, multiple and single strikes, transportation conditions.

Low voltage complete device meet the requirements of:

  • climatic versionUHL, location category 4, state standard 15150-69
  • degrees of  casing protection from water 5Х state standard 14254-96
  • state standard 30546.1-98, state standard 30546.2-98, state standard 30546.3-98 in the field of seismic resistance to seismic influences intensity 9 points on a scale MSK-64 and setting items in buildings elevation up to +10,0m
  • group of mechanical version М43 for single strikes state standard 17516.1-90
  • group of mechanical versionМ7 for multiple strikes state standard 17516.1-90
  • transportation conditioning - M (middle) state standard 23216-78

Transf work boats - seismic resistance
Transf work boats - seismic resistance

"SVEL", LLC

Transf work boats  ZNOL-SVEL-35 and 3NOL-SVEL-10 meet the requirements of state standard 17516.1-90, state standard  30546.1-98, state  30546.2-98, state standard 16962.2-90,  NP-031-01 in the field of resistance to seismic influences MRZ intensity 9 points on a scale MSK-64 and elevation up to +30 m

 

Porcelaneous insulators - seismic resistance
Porcelaneous insulators - seismic resistance

"Volta", CJSC

Stand off rod porcelaneous insulators series IOS meet the requirements state standard 17516.1-90, state standard 30546.1-98, state standard 30546.2-98, state standard 30546.3-98 state standard 16962.2-90, PNAE G 7-002-86, NP-031-01, STO 56947007-29.060.10.117-2012 in the field of seismic resistance in seismic influences intensity 9 points (on a scale MSK-64) and setting in buildings elevation up to +10,0 m

Electric convectors - seismic resistance
Electric convectors - seismic resistance

"Оniks", ALC

Electric convectors series «MISOT-E» and «MISOT-EV» meet the requirements state standard 17516.1-90, state standard 30546.2-98, state standard 16962.2-90,  NP-031-01 in the field of seismic resistance to seismic influences MRZ intensity 9 points on a scaleв MSK-64 and elevation in buildings up to +30 m; 1-st category of seismic resistance on NP-031-01

Invertors - seismic resistance
Invertors - seismic resistance

"Plant Invertor", JSC

Invertors of the type I-PTPT-433(577)-400-50-UHL4 meet the requirements state standard 17516.1-90, state standard 30546.1-98, state standard 30546.2-98, state standard 30546.3-98 state standard 16962.2-90, PNAE G 7-002-86, NP-031-01, NP-064-05, МТ 1.2.2.04.0069-2012 in the field of resistance to seismic influences intensity 9 points on a scale MSK-64 and setting items in buildings elevation up to +30,0 m inclusive in case of following the developed recommendations

 

 Voltage stabilizers - seismic resistance
Voltage stabilizers - seismic resistance

"Elektromash", CJSC

Voltage stabilizers of the type STS-ZN-1-63-380 UZ NPP, STS-ZN-1-100-380 UZ NPP, STS-ZN-1-160-380 UZ NPP - meet the requirements of state standard 17516.1-90, state standard 30546.1-98, state standard 30546.2-98, state standard 30546.3-98 state standard 16962.2-90,  PNAE G 7-002-86, NP-031-01, NP-064-05, МТ 1.2.2.04.0069-2012 in the field of seismic resistance to seismic influences intensity 9 points on a scale MSK-64 and setting items in buildings elevation up to +30 m inclusive; 1 category of seismic resistance on NP k-031-01

 

Control cabinet OCCC- seismic resistance
Control cabinet OCCC- seismic resistance

"Elektromash", CJSC

Operation current control cabinets OCCC, consist of cabinet OCCC-2406-20(40)-230-UHL4 IP20 and storage batteries cabinet (cabinet SB) meet the requirements of state standard 17516.1-90, state standard 30546.1-98, state standard 30546.2-98, state standard 30546.3-98 state standard 16962.2-90,  PNAE G 7-002-86, NP-031-01, NP-064-05, МТ 1.2.2.04.0069-2012 in the field of seismic resistance in seismic influences intensity 9 points (on a scale MSK-64 and setting items in buildings elevation up to +30 m; - I category seismic resistance NP-031-01

High-voltage frequency transformers – seismic resistance
High-voltage frequency transformers – seismic resistance

Concern SIEMENS, Germany

High-voltage frequency transformers of Perfect Harmony type with water cooling meet the requirements of state standard  17516.1-90, state standard 30546.1,2,3-98,  PNAE G-7-002-86, NP-031-0 in the field of seismic resistance influences intensity 9 points (on a scale MSK-64), elevation to +10 m